Cement dams · Concrete reservoirs · Water tanks

Cement Reservoir Repair & Restoration

A cracked or seeping cement reservoir can usually be restored instead of rebuilt. Damtech prepares the concrete and lines it with a heat-bonded torch-on bitumen membrane so it holds water again.

Last updated

CEMENT RESERVOIR REPAIR

Restore a leaking cement reservoir instead of rebuilding it

If the walls and floor are still sound, a leaking cement reservoir or concrete dam can be relined with a bonded torch-on bitumen membrane so it holds water again.

  • Assessed before quoting
  • Bonded torch-on membrane
  • Floor, walls and outlets
Torch-on bitumen waterproofing for a concrete water-retaining structure
Cement damsConcrete reservoirsWater tanks

WHY IT MATTERS

Key Benefits

  • Restores a leaking cement reservoir without rebuilding it

  • Membrane is heat-bonded to the primed concrete, floor and walls

  • 3 mm and 4 mm torch-on membranes

  • Laps, corners, outlets and pipe penetrations detailed with extra layers

  • 15–20 year typical service life on well-prepared concrete (conditions apply; not a guarantee)

  • Supplier-backed material warranty where stated in the quotation

TECHNICAL DETAIL

Cement reservoir repair at a glance

Structures
Round cement dams, concrete reservoirs, water tanks, canals
System
Torch-on modified bitumen membrane
Membrane thickness
3 mm and 4 mm
Typical service life
Typically 15–20 years*
Before lining
Clean, dry, primed concrete; structural cracks repaired first

Why cement reservoirs and concrete dams leak

Concrete is rigid and the ground under it is not. Seasonal movement, heat and age open cracks in the floor and at the joint where the wall meets the floor. Older plaster and cement coatings lose their bond and let water in behind them, and pipes cast through the wall often leak around the sleeve.

The signs are a water level that drops when nothing is being used, wet patches or white salt stains on the outside of the wall, and green growth along a crack line. The sooner it is assessed the smaller the repair, because water moving through a crack keeps widening it.

Dam sealer or a bonded lining?

Pour-in dam sealers and brush-on cement coatings are sold for leaking dams. They can help where seepage is slow and spread across a surface. They are a poor match for a rigid reservoir with cracks or joints that move, because a thin coating cracks again when the concrete moves.

A torch-on bitumen membrane is a continuous sheet, 3 mm or 4 mm thick, bonded to the concrete and lapped at every joint. It bridges hairline cracks and moves with the structure. That is why we recommend relining when a cement reservoir has already been patched or sealed and is leaking again.

How Damtech restores a cement reservoir

We start with photos or a site visit to check that the walls and floor are sound and to find where the water is getting out. The reservoir is emptied, cleaned and left to dry. Loose plaster and failed coatings are removed, and the concrete is primed.

The membrane is then torched on in planned runs across the floor and up the walls, with continuous laps. Corners, the wall-to-floor joint, outlets and pipe penetrations get extra layers, because that is where rigid reservoirs leak first. Torch-on is hot work and is done by trained applicators with fire precautions in place.

When structural repair comes first

A membrane waterproofs the reservoir. It does not hold a failing wall together. Wide or stepped cracks, bulging walls and exposed or rusting reinforcing steel must be repaired before lining, and we say so in the written quote before any work starts.

Where the concrete is past saving, a corrugated steel reservoir with a PVC liner can be the more economical replacement. We quote that as a separate option so you can compare the two.

What we need to quote

Send the diameter (or length and width), the wall height, photos of the inside and outside, and the town. Tell us what the water is used for and whether the reservoir can be emptied. Most cement reservoir repairs can be priced from that; larger or badly cracked structures are inspected on site first.

HOW IT WORKS

Our Simple Service Process

From your first enquiry to final handover, Damtech keeps the process clear, practical and hassle-free.

  1. Request a Quote

    Tell us what you need, including dam linings, waterproofing, steel water tanks, maintenance or repair.

    No obligation. No pressure.

  2. Site Review

    We assess the application, site conditions and practical requirements for your project.

    Thorough. Practical. Honest.

  3. Tailored Recommendation

    We recommend a suitable material, system and installation approach for your site.

    Clear recommendations.

  4. Delivery & Support

    Our team delivers the agreed service with clear communication and practical workmanship.

    On time. On standard.

OUR PROJECTS

Cement reservoir and concrete dam projects

Quality materials, expert installation and practical solutions for dam linings, waterproofing and water storage.

View all Damtech projects
  • Torch-on bitumen waterproofing on an 18 m diameter concrete dam near Tzaneen

    Tzaneen, Limpopo

    Limpopo

    Concrete dam waterproofing

    Torch-On Bitumen Concrete Dam — 18 m Diameter

    Torch-on bitumen waterproofing for a round concrete dam with an 18 m diameter. Approximately 255 m² circular base footprint, calculated from the 18 m diameter. This is a geometric base-area estimate — not the measured installed membrane quantity. Installed membrane area is higher once walls are included — roughly +130 m² if the wall is 2.3 m high all around (π × 18 m × 2.3 m), plus overlaps, detailing and waste.

    Tzaneen round concrete dam waterproofed with torch-on bitumen — 18 m diameter, approximately 255 m² base footprint.

    View project
  • Bitumen torch-on waterproofing project completed by Damtech in Hoedspruit

    Hoedspruit, Limpopo

    Limpopo

    Bitumen torch-on dam lining

    Hoedspruit Bitumen Torch-On Waterproofing

    550 m² bitumen torch-on lining for cement / structured dam waterproofing.

    Hoedspruit structured dam waterproofed with 550 m² bitumen torch-on lining for Lowveld water storage.

    View project